V/Ethernet 4221 Condor
User’s Guide
Document No. UG04221-000, REVB
Release date: July 1994
Copyright 1994
Interphase Corporation
All Rights Reserved
Vista de página 0
1 2 3 4 5 6 ... 123 124

Resumo do Conteúdo

Página 1 - User’s Guide

V/Ethernet 4221 Condor User’s GuideDocument No. UG04221-000, REVBRelease date: July 1994Copyright 1994Interphase CorporationAll Rights Reserved

Página 3 - Disclaimer

Chapter 3 - MACSI Host Interface88Command Options Table 3-30. Command OptionsInterrupt enable (IE) As defined in Common IOPB Structures. In-line gathe

Página 4 - Trademark Acknowledgments

Transmit -- In-Line Gathers89Table 3-31. Transmit - In-Line GathersNumber of Elements This field contains the number of gather elements included in th

Página 5 - TABLE OF CONTENTS

Chapter 3 - MACSI Host Interface90Receive The host provides the controller with Receive commands, which specify the host resources to be used for inco

Página 6

Receive91Command Code This field must contain 0x60 to execute the Receive IOPB. Command Options Table 3-33. Command OptionsInterrupt enable As defined

Página 7

Chapter 3 - MACSI Host Interface92Source Address When so monitoring the network, the source address for the incoming frame will be contained in this f

Página 8

Initialize Multiple Completions93Initialize Multiple Completions This command enables the controller to return multiple completed commands to the host

Página 9 - LIST OF FIGURES

Chapter 3 - MACSI Host Interface94Command Options No special options are available for this command. Refer to Common IOPB structures for defined opti

Página 10

Report Network Statistics95Report Network Statistics Table 3-36. Report Network StatisticsThe Report Network Statistics Command can be used to obtain

Página 11 - LIST OF TABLES

Chapter 3 - MACSI Host Interface96Command Options Table 3-37. Command OptionsInterrupt enable (IE) As defined in Common IOPB Structures. Port selector

Página 12

Network Statistics Block97Network Statistics Block Table 3-38. Network Statistics BlockData Valid Indicator When the data is transferred to the host,

Página 13 - INTRODUCTION

LIST OF TABLESxivTable 2-1. Condor Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 14 - Features

Chapter 3 - MACSI Host Interface98Transmits Failed This field contains the number of transmit commands for the particular port that could not be trans

Página 15 - Functional Description

99APPENDIX A SPECIFICATIONSVMEbus SpecificationsDTB Master A16, A24, A32, D08 (EO), D16, D32: BLT, D64: BLTDTB Slave A16, D08 (EO), D16, D32Request

Página 16 - Local Bus

100Appendix AMechanical (Nominal)Length 233 mmWidth 160 mmThickness 20 mmWeight .45 KgOperating EnvironmentTemperature 0-55 degrees CentigradeRelative

Página 17 - CPU Core

101APPENDIX B CONNECTOR PINOUTS AND CABLINGOverviewThis chapter contains the connector pinouts and cabling information needed for various Condor confi

Página 18 - CPU/LBUS Interface

102Appendix BVMEbus ConnectorsThe following tables show the pin numbers and signal description for the P1 and P2 VMEbus Connectors.• Table C-39 - P1 C

Página 19 - HARDWARE INSTALLATION

103VMEbus ConnectorsP2 Connector Row B Only VersionTable C-40. P2 Connector For Motherboards Which Only Uses P2 Row BPINRow A Signal Mnemonic Row B Si

Página 20

104Appendix BEthernet Connectors and PinoutsThe Condor supports both the AUI and 10BaseT versions of the Ethernet 802.3 specification. The card will h

Página 21 - DAUGHTER

105Ethernet Connectors and PinoutsAUI Connector SignalsThe AUI signals and connector pinout for the DB15 connector are shown in the following table.Ta

Página 22

106Appendix BRS232 Connector and CableTable C-43. Serial Connector Pinouts (SPA and SPB)NOTE: The same cable for the second Serial Port for PC compa

Página 23

107APPENDIX C ERROR CODESThe Return Status word in the command response contains information pertaining to the status of the IOPBs returnedin the Comm

Página 24

xvTable 3-36. Report Network Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95Tab

Página 25

108Appendix B

Página 26 - Diagnostic LEDs

INDEX109Numerics82596 4, 81, 82AAA 79Abort ALL (AA) 79Abort ANY (AN) 79Abort Pending (AP) 81Abort Report (AR) 80, 81Air Flow 100AN 79ANY 91AP 81AR

Página 27 - Board Status LEDs

110EX 63Exception (EX) 63Ffeature list 2fetch offboard entry (FOB) 60Fetch offboard in progress (FIP) 60field offset 54FIP 60firmware revision level 6

Página 28 - Motherboard Jumper Settings

111PPFM 86PM 75, 81POST mode 15power requirements 99Product Code 65, 68Program factory MAC address (PFM) 86Promiscuous mode (PM) 75, 81QQECR 60QMS

Página 30 - J14 Firmware Option Jumpers:

1CHAPTER 1 INTRODUCTIONIntended AudienceInterphase wrote this manual for its customers. It is intended for a highly technical audience, specifically,

Página 31

Chapter 1 - Introduction2ConventionsThis section details many of the writing conventions used throughout the manual. In addition, it gives many of th

Página 32

Options3OptionsInterphase Corporation offers the following Condor options:• Dual Channel Ethernet (AUI)• Dual Channel Ethernet (10BaseT)• 3 Channel Et

Página 33

Chapter 1 - Introduction4Ethernet Front End Channel (FEC)The 82596CA® Local Area Network (LAN) Co-processor is used as the FEC Ethernet controller. Th

Página 34

VMEbus Short I/O Interface5VMEbus Short I/O InterfaceThe VMEbus Short I/O interface allows for VMEbus host and onboard CPU communications. The host is

Página 35

Chapter 1 - Introduction6interrupt handler outputs an interrupt vector number for the non-DMA engine interrupts or requests access to the LBUSfor a DM

Página 36

7CHAPTER 2HARDWARE INSTALLATIONOverviewBefore attempting installation, read this chapter thoroughly to insure the safe installation of the Condor int

Página 38

Chapter 2 - Hardware Installation8The daughter card installation procedure will vary depending on the desired configuration. Variables include:• Sing

Página 39

Overview9Figure 2-1. 10BaseT Condor Motherboard Layout (PB04221-000)LED 1LED 2LED 3LED 4LED 5LED 6LED 7SPBSPAJ14J15J16J18J12J13P2P1J23J24J26J25J19J2

Página 40

Chapter 2 - Hardware Installation10Figure 2-2. Single Channel AUI or 10BaseT Motherboard Layout (PB004221-001)LED 1LED 2LED 3LED 4LED 5LED 6SPBSPAJ1

Página 41

Overview11Figure 2-3. AUI Condor Motherboard Layout (PB04221-000)LED 1LED 2LED 3LED 4LED 5LED 6SPBSPAJ14J15J16J18J12J13P2P1J23J24J26J25J19J20J21J22

Página 42

Chapter 2 - Hardware Installation12Figure 2-4. 10BaseT Condor Motherboard Layout (PB04221-001)LED 1LED 2LED 3LED 4LED 5LED 6LED 7SPBSPAJ10 J14 J16J1

Página 43

Overview13Figure 2-5. AUI Condor Motherboard Layout (PB04221-001)LED 1LED 2LED 3LED 4LED 5LED 6SPBSPAJ10 J14J16J18J12J15P2P1J23J24J26J25J19J20J21J2

Página 44

Chapter 2 - Hardware Installation144221 Condor Hardware Installation ProceduresFor proper installation of the Condor, it is imperative that you use th

Página 45

4221 Condor Hardware Installation Procedures15Board Status LEDsLEDs 1, 2, 3, and 4 are Board Status LEDs which provide the following functions:• Power

Página 46

Chapter 2 - Hardware Installation16Table 2-4. Run Mode LED MatrixStep 3. Set Onboard Motherboard Jumpers Set all onboard jumpers so that the Condor i

Página 47

4221 Condor Hardware Installation Procedures17J9 +12 VOLTS Flash Programming Protect: IN: +12 Volt power connected to EPROM socket.OUT: +12 Volt power

Página 48

Copyright Notice Copyright 1993, 1994 by Interphase CorporationAll rights reservedNo part of this publication may be stored in a retrieval system, tr

Página 49

Chapter 2 - Hardware Installation18(Pins 5-6) Console Message DisableIN = DisableOUT = Enable(Pins 7-8) GDB Enable PointIN = GDB Initialized On ExitOU

Página 50

4221 Condor Hardware Installation Procedures19Table 2-6. Secondary Short I/O* Factory DefaultJ16 Primary Short I/O Size / Reset Enable:Table 2-7. Prim

Página 51

Chapter 2 - Hardware Installation20J18 Primary Channel Address Modifiers:IN = Primary Channel Address Modifiers 29 or 2D OUT = Primary Channel Addres

Página 52

4221 Condor Hardware Installation Procedures21J19, J20, J21 & J22 Primary Short I/O Base Address:Refer to the following tables when setting Primar

Página 53

Chapter 2 - Hardware Installation22Table 2-8. Primary Base Address For 2K Short I/O NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADDRESS J19 PIN SETTI

Página 54

4221 Condor Hardware Installation Procedures23Table 2-9. Primary Base Address For 1K Short I/O NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADDRESS J1

Página 55

Chapter 2 - Hardware Installation24Table 2-10. Primary Base Address For 512 Byte Short I/ONOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADDRESS J19 PIN

Página 56

4221 Condor Hardware Installation Procedures25Table 2-10. Primary Base Address For 512 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Lo

Página 57

Chapter 2 - Hardware Installation26Table 2-11. Primary Base Address For 256 Byte Short I/O NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADDRESS J19 PI

Página 58

4221 Condor Hardware Installation Procedures27Table 2-11. Primary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Lo

Página 59

For AssistanceTo place an order for an Interphase product, call:Sales Support: (214) 919-9000For assistance using this, or any other Interphase produ

Página 60

Chapter 2 - Hardware Installation28Table 2-11. Primary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADD

Página 61

4221 Condor Hardware Installation Procedures29Table 2-11. Primary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Lo

Página 62

Chapter 2 - Hardware Installation30Table 2-11. Primary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADD

Página 63 - Step 6. Cabling Procedure

4221 Condor Hardware Installation Procedures31Table 2-11. Primary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Lo

Página 64 - RS232 Connectors And Cables

Chapter 2 - Hardware Installation32Table 2-11. Primary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADD

Página 65 - MACSI HOST INTERFACE

4221 Condor Hardware Installation Procedures33J23, J24, J25 & J26 Secondary Short I/O Address:Refer to the following tables when setting Secondary

Página 66 - Contiguous Data Allocation

Chapter 2 - Hardware Installation34Table 2-12. Secondary Base Address For 2K Short I/ONOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADDRESS J23 PIN SET

Página 67 - MACSI Organization

4221 Condor Hardware Installation Procedures35Table 2-13. Secondary Base Address For 1K Short I/O NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADDRESS

Página 68

Chapter 2 - Hardware Installation36Table 2-13. Secondary Base Address For 1K Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADDRESS

Página 69 - 1514131211109876543210

4221 Condor Hardware Installation Procedures37Table 2-14. Secondary Base Address For 512 Byte Short I/O NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)A

Página 70 - Master Control Register (MCR)

TABLE OF CONTENTSviCHAPTER 1INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 71 - Onboard Command Queue Entry

Chapter 2 - Hardware Installation38Table 2-14. Secondary Base Address For 512 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)A

Página 72 - Offboard Command Queue Entry

4221 Condor Hardware Installation Procedures39Table 2-14. Secondary Base Address For 512 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F= OUT (L

Página 73 - Work Queue Number

Chapter 2 - Hardware Installation40Table 2-14. Secondary Base Address For 512 Byte Short I/O (ContinuedADDRESS J23 PIN SETTINGS J24, J25, J26 PIN SETT

Página 74 - Command Response Block (CRB)

4221 Condor Hardware Installation Procedures41Table 2-15. Secondary Base Address For 256 Byte Short I/O NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)A

Página 75 - IOPB Length

Chapter 2 - Hardware Installation42Table 2-15. Secondary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)A

Página 76 - Transfer Count

4221 Condor Hardware Installation Procedures43Table 2-15. Secondary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F= OUT (L

Página 77 - Product Variation

Chapter 2 - Hardware Installation44Table 2-15. Secondary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)A

Página 78 - Firmware Revision Date

4221 Condor Hardware Installation Procedures45Table 2-15. Secondary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (

Página 79 - Controller Statistics Block

Chapter 2 - Hardware Installation46Table 2-15. Secondary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)A

Página 80 - Failed Transmits

4221 Condor Hardware Installation Procedures47Step 4. Set Daughter Card Jumpers And TerminationsThe following daughter card settings are discussed:• E

Página 81

viiCommand Response Block (CRB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 82 - Common IOPB Structures

Chapter 2 - Hardware Installation48Ethernet Single Channel AUI/10BaseT Daughter CardCOMPONENT SIDE Figure 2-6. Ethernet Single Channel AUI/10Ba

Página 83

4221 Condor Hardware Installation Procedures49Dual Channel 10BaseT Ethernet Daughter CardCOMPONENT SIDE Figure 2-7. Dual Channel 10BaseT Ethernet Da

Página 84

Chapter 2 - Hardware Installation50Ethernet Dual Channel AUI Daughter CardCOMPONENT SIDE Figure 2-8. Ethernet Dual Channel AUI Daughter CardNOTE: L

Página 85 - Initialize Controller

4221 Condor Hardware Installation Procedures51Step 5. Power Off SystemOnce the board is configured, ensure that the host system and peripherals are tu

Página 86 - Number of CQE Entries

Chapter 2 - Hardware Installation52RS232 Connectors And CablesThere are two 10 pin connectors (2x5 Headers) which are used as the RS232 port cable con

Página 87 - Special Network Options

53CHAPTER 3MACSI HOST INTERFACEIntroductionThis chapter defines the MACSI host interface for the Interphase V/Ethernet 4221 Condor. The Condor and it

Página 88 - Offboard CRB host address

Chapter 3 - MACSI Host Interface54Field OffsetThe value in the far left column specifies the field offset. This value measures increments of 16 bits

Página 89 - MAC Control/Status

System Interface55System Interface This section defines how the host communicates with the controller. The shared memory interface is defined, and ea

Página 90

Chapter 3 - MACSI Host Interface56The Master Command Entry (MCE) and Command Queue Entries (CQE) are used to queue commands from the hostto the contr

Página 91

Master Control Status Block (MCSB)57Master Control Status Block (MCSB)The MCSB consists of a Master Status Register, which is used to report informati

Página 92 - MAC status/control

viiiMAC status/control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 93

Chapter 3 - MACSI Host Interface58Master Control Register (MCR)The MCR provides the host with infrequently used services. These bits are both set and

Página 94

Onboard Command Queue Entry59Onboard Command Queue Entry The host issues a command to the controller through a Command Queue Entry (CQE). Two types a

Página 95

Chapter 3 - MACSI Host Interface60Fetch offboard (FOB) Setting this bit makes the Command Queue entry an offboard entry. Please see the following sect

Página 96 - MAC returned information

Offboard Command Queue Entry61DMA Transfer Control Word This field specifies how the controller should DMA transfer the data from host memory. This f

Página 97 - Change Default Node Address

Chapter 3 - MACSI Host Interface62Command Response Block (CRB)The CRB is used by the controller to post completed commands back to the host. It consi

Página 98

Command Response Block (CRB)63Error (ER) This bit is set with Command Complete when a returned IOPB completed with an error. Errored commandsare nev

Página 99 - Transmit

Chapter 3 - MACSI Host Interface64Multiple Completed Returned IOPB Structure When multiple commands are returned from the controller to the host with

Página 100 - Transmit -- In-Line Gathers

Configuration Status Block (CSB)65Configuration Status Block (CSB)The controller uses the CSB to report the firmware and hardware configuration upon p

Página 101 - Buffer address

Chapter 3 - MACSI Host Interface66Firmware Revision Level The firmware revision level, represented as a 3-digit ASCII value. Firmware Revision Date Th

Página 102 - Receive

Controller Statistics Block67Controller Statistics Block This space was used to report network statistics in the original Eagle MACSI implementation f

Página 103 - Command Code

ixOperating Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 104 - Source Address

Chapter 3 - MACSI Host Interface68Transmit Commands Submitted Total number of attempted frame transmissions (successful and unsuccessful). Transmit DM

Página 105

Controller Statistics Block69Transmit Completions Posted to Host Total number of frame completions posted to the Command Response Block and Returned I

Página 106

Chapter 3 - MACSI Host Interface70IO Parameter Blocks (IOPBs) This section provides a detailed description of each of the commands used by the host to

Página 107 - Report Network Statistics

Common IOPB Structures71Command Code This field specifies the command to be executed. Particular values are noted for each of the individual commands

Página 108 - Timer Interval

Chapter 3 - MACSI Host Interface72Address modifier This field contains the VMEbus address modifier used for the transfer. Refer to your system documen

Página 109 - Network Statistics Block

Initialize Controller73Initialize Controller This command allows the host to specify global configuration parameters, and initializes the controller f

Página 110

Chapter 3 - MACSI Host Interface74Controller Initialization Block (CIB)The CIB contains the actual values to use when initializing the controller. It

Página 111 - SPECIFICATIONS

Controller Initialization Block (CIB)75Special Network Options Originally, this field allowed the host to set several network related options, such as

Página 112 - Reliability

Chapter 3 - MACSI Host Interface76A value between 1 and 0x20 (40 decimal) causes the controller, after being granted the bus, to transfer data until 1

Página 113 - CONNECTOR PINOUTS AND CABLING

MAC Control/Status77MAC Control/Status This command provides a host driver with two distinct levels of service to an Ethernet port located on the 4221

Página 114 - VMEbus Connectors

LIST OF FIGURESxiiFigure 1-1. 4221 Condor Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 115

Chapter 3 - MACSI Host Interface78Table 3-22. MAC Control / StatusCommand Code This field must contain 0x43 to execute the MAC Control IOPB. MAC Contr

Página 116 - 10BaseT Connector Signals

MAC Control/Status79Command Options Table 3-23. Command OptionsInterrupt Enable (IE) Defined in Common IOPB Structures. Set MAC options (SM) When this

Página 117 - AUI Connector Signals

Chapter 3 - MACSI Host Interface80Abort Report (AR)Setting this bit causes commands aborted with either the AA or the AN bit to be reported back to th

Página 118 - RS232 Connector and Cable

MAC Control/Status81Setting this bit resets the port: promiscuous mode is disabled, multicast is disabled, any supplied multipleindividual addresses a

Página 119 - ERROR CODES

Chapter 3 - MACSI Host Interface82Table 3-25. Intel 82596 Transmit Status / ControlBackoff method (BM) (p. 4-131) This parameter determines when to st

Página 120 - Appendix B

MAC Control/Status83Table 3-26. Intel 82596 Receive Status / ControlSave bad frames (SB) (p. 4-129)When set bad frames (CRC error, Alignment error, et

Página 121

Chapter 3 - MACSI Host Interface84Time domain reflectometry test (TDR) (p. 4-150) This operation activates the Time Domain Reflectometry test. The re

Página 122

Change Default Node Address85Change Default Node Address This command is used to change the 48 bit physical address associated with any of the attache

Página 123

Chapter 3 - MACSI Host Interface86Command Options Table 3-28. Command OptionsInterrupt enable (IE)As defined in the Common IOPB Structures. Update use

Página 124

Transmit87Transmit The Transmit command causes the controller to DMA transfer the specified frame from host memory, and thentransmit it (if possible)