Interphase Tech 4538 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Unidades de distribuição de energia (PDUs) Interphase Tech 4538. Interphase Tech 4538 User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 149
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - Hardware Reference Manual

4538 PMC® T1/E1/J1 Communications ControllerHardware Reference ManualDocument No. UG4538-001$Print Date: 2FWREHU

Página 2

Contentsiv Interphase CorporationIn Situ EPLD Programming

Página 3 - Trademark Acknowledgments

T1/E1/J1 Framer Initialization78 Interphase CorporationSEC/FSC ConfigurationThe SEC/FSC signal of the QuadFALC is connected to CPM and is used for the

Página 4 - Assistance

Chapter 3: Programming the Peripherals4538 Hardware Reference Manual 79RCLK1 is one of the four channels’ internally-generated receive route clocks (R

Página 5 - END-USER LICENSE AGREEMENT

T1/E1/J1 Framer Initialization80 Interphase CorporationRCLK1 Configuration as TDM bus clock8 KHz synchronization pulse generated by the internal DCO1-

Página 6

Chapter 3: Programming the Peripherals4538 Hardware Reference Manual 81not go to a continuous level, but is the free running frequency of DCO-R. Since

Página 7

T1/E1/J1 Framer Initialization82 Interphase CorporationFraming and Line Coding InitializationCommon InitializationT1 Specific InitializationE1/E1-CRC4

Página 8

Chapter 3: Programming the Peripherals4538 Hardware Reference Manual 83E1 Non-CRC4 Specific InitializationE1-CRC4 Specific InitializationClock Synchro

Página 9

The Ethernet Port Initialization84 Interphase CorporationTransmit Pulse ShapeFor each type of Line Build-Out (LBO), the shape of the transmit pulse mu

Página 10 - Interphase Corporation

Chapter 3: Programming the Peripherals4538 Hardware Reference Manual 85For a simple SMC1 controller example in polling mode:See Boot Firmware: app\c\m

Página 11 - List of Figures

The TTY Framer Initialization86 Interphase Corporation

Página 12

44538 Hardware Reference Manual 874Accessing the 4538 on the PCI SidePowerSpan Configuration by the PCI HostSeveral elements of the PowerSpan are auto

Página 13 - List of Tables

4538 Hardware Reference Manual vList of FiguresFigure 1-1. 4538 Structure...

Página 14

Controlling the PCI-to-Local Interrupt88 Interphase CorporationFor a normal use, the card should be reset by the PCI host (if needed) using only the–S

Página 15 - List of Examples

Chapter 4: Accessing the 4538 on the PCI Side4538 Hardware Reference Manual 89Local to PCI Interrupt (–INTA)The PowerQUICC II can generate an interrup

Página 16

Access to the FLASH EEPROM Through PCI90 Interphase CorporationWhen the processor is running, the PCI bus has access to all the elements connected to

Página 17 - Using This Guide

Chapter 4: Accessing the 4538 on the PCI Side4538 Hardware Reference Manual 91Example 4-5. FLASH Read and Write Routines (From PCI Side)

Página 18 - Icon Conventions

Serial EEPROM Connected to the PowerSpan92 Interphase CorporationFLASH EEPROM Programming AlgorithmsThe boot memory is a 4Mx8 AMD 29LV033 FLASH device

Página 19 - Text Conventions

Chapter 4: Accessing the 4538 on the PCI Side4538 Hardware Reference Manual 93In Situ EPLD ProgrammingGlue logic is implemented in some EPLDs that can

Página 20 - Interphase WWW/FTP Site

PCI Deadlock Situations94 Interphase CorporationExample: The PCI host sets the DMA buffer descriptors into the local memory, and then it runs the DMA

Página 21

54538 Hardware Reference Manual 955Connectors and Front PanelConnector PlacementFigure 5-1. Connectors on the Component SideFigure 5-2. Connectors a

Página 22

Front Panel96 Interphase CorporationFront PanelFigure 5-3. Connectors and Leds on front panelLED DescriptionsCPU_LED1: Board user-programmable green

Página 23 - 1Hardware Description

Chapter 5: Connectors and Front Panel4538 Hardware Reference Manual 97Ethernet 10/100 RJ45 Connector J3Table 5-1. RJ48 Connectors J1 and J2Signal,1

Página 24 - The PowerQUICC II

List of Figuresvi Interphase Corporation

Página 25 - PowerQUICC II Resets

PMC Connectors98 Interphase CorporationTTY Serial Port J4A 2.5mm stereo jack connector provides a connection to an asynchronous serial device such as

Página 26 - PCI Local Space Mapping

Chapter 5: Connectors and Front Panel4538 Hardware Reference Manual 99 1RWFRQQHFWHG 1RWFRQQHFWHG *1' 6XSSO\ *URXQG 1RWFRQQHFWHG 3

Página 27

PMC Connectors100 Interphase Corporation 1RWFRQQHFWHG 1RWFRQQHFWHG 3$5 7ULVWDWHELGLUHFWLRQDO 3&,3DULW\ *1' 6XSSO\ *URXQG 9

Página 28 - 6 Interphase Corporation

Chapter 5: Connectors and Front Panel4538 Hardware Reference Manual 101 3&,7', ,QSXW -7$*7HVW,QSXW%HFDXVHWKHERDUGGRHVQRWVXSSRUWWKH

Página 29 - Memory Controllers

PMC Connectors102 Interphase Corporation 3$' 7ULVWDWHELGLUHFWLRQDO 3&,$GGUHVV'DWD &%( 7ULVWDWHELGLUHFWLRQDO 3&,%

Página 30 - 7DEOHCPM Port B Usage

Chapter 5: Connectors and Front Panel4538 Hardware Reference Manual 103PMC Connector P4PMC connector P4 supports the four E1/T1 lines and two TDM buss

Página 31 - 7DEOHCPM Port C Usage

PMC Connectors104 Interphase Corporation 1RWFRQQHFWHG 1RWFRQQHFWHG 1RWFRQQHFWHG 1RWFRQQHFWHG 1RWFRQQHFWHG 1RWFRQQHFWHG 1RWF

Página 32 - CPM TDM Busses

Chapter 5: Connectors and Front Panel4538 Hardware Reference Manual 105Debug Port J5On the 4538, a 2x8-pin connector can be implemented to provide acc

Página 33 - Ethernet 10/100BaseT

ISP Enable Jumper JP1106 Interphase CorporationWARNINGJ5 Debug Connector is not compliant to PMC component height specification. It should be removed

Página 34 - User-Programmable LEDs

Chapter 5: Connectors and Front Panel4538 Hardware Reference Manual 107Connector SummaryCarrier Card SpecificationCompactPCI Carrier CardInterphase ha

Página 35 - The PCI Bridge

4538 Hardware Reference Manual viiList of TablesTable 1-1. PCI Local Space Mapping ...

Página 36 - Description

Carrier Card Specification108 Interphase CorporationJ3 Columns 15 to 19 are unused.J5 Columns 14 to 19 are unused. 30&,2 30&,2 30&

Página 37 - Register Description

Chapter 5: Connectors and Front Panel4538 Hardware Reference Manual 109Signals printed in bold in Table 5-8 and Table 5-9 shall be routed to the corre

Página 38

6435 Rear Transition Module110 Interphase Corporation6435 Rear Transition ModuleFigure 5-6. 8-Port 6435 Rear Transition Module Layout

Página 39

Chapter 5: Connectors and Front Panel4538 Hardware Reference Manual 111NOTEPMC site 1 (J14) corresponds to lines 5 to 8, PMC site 2 (J24) corresponds

Página 40

6435 Rear Transition Module112 Interphase Corporation

Página 41

A4538 Hardware Reference Manual 113AMechanical InformationPMC Card Dimensions

Página 42 - PCI to Local Interrupt (ATN)

Carrier Card Dimension Requirements114 Interphase CorporationCarrier Card Dimension Requirements.H\3RVLWLRQIRU

Página 43

4538 Hardware Reference Manual 115BibliographyIndustry StandardsEIA-232-D: Interface Between Data Terminal Equipment and Data Circuit-TerminatingEquip

Página 44

116 Interphase CorporationPICMG 2.0 CompactPCI SpecificationPICMG 2.5 CompactPCI Computer Telephony SpecificationPICMG 2.1 CompactPCI Hot Swap Specifi

Página 45 - /RFDO0HPRU\6SDFH

4538 Hardware Reference Manual 117ANSI T1.107-1995: Digital Hierarchy - Formats Specifications.ANSI T1.646-1995: Broadband ISDN - Physical Layer Speci

Página 46

List of Tablesviii Interphase CorporationTable 5-3. J4 TTY Serial Connector ...

Página 47

118 Interphase Corporation1 specification and test principles.ETSI ETS 300 166 - Transmission and Multiplexing (TM); Physical and electrical character

Página 48 - 3&,,26SDFH

4538 Hardware Reference Manual 119Infineon PEB22554 / QuadFALC T1/E1/J1 framer4XDG)UDPLQJDQG/LQH,QWHUIDFH&RPSRQHQWIRU(7-4XDG)$/&am

Página 49 - Board Equipment Register

120 Interphase Corporation

Página 50

4538 Hardware Reference Manual 121GlossaryAAL ATM Adaptation Layer Service-dependent sublayer of the data link layer. The AAL accepts data from differ

Página 51 - The FLASH EEPROM Boot Memory

Glossary122 Interphase CorporationBRI Basic Rate Interface ISDN interface composed of two B Channels and one D Channel for circuit-switched communicat

Página 52 - The QuadFALC T1/E1/J1 Framer

Glossary4538 Hardware Reference Manual 123DSX1 Cross-connection point for DS1 signals.DTE Data Terminal Equipment Device at the user end of a user-net

Página 53 - XPM0 XPM1 XPM2 XPM0 XPM1 XPM2

Glossary124 Interphase CorporationITU-T International Telecommunication Union Telecommunication Standardization Sector Interna-tional body that develo

Página 54

Glossary4538 Hardware Reference Manual 125PDU Protocol Data Unit A message of a given protocol comprising payload and protocol-specific control inform

Página 55 - The Ethernet Transceiver

Glossary126 Interphase CorporationSTS Synchronous Transport SignalSTS1 Synchronous Transport Signal level 1 Basic building block signal of SONET, oper

Página 56 - TDM Bus Configurations

When using this index, keep in mind that a page number indicates only where referenced material begins.It may extend to the page or pages following th

Página 57

4538 Hardware Reference Manual ixList of Examples([DPSOH 3RZHU6SDQ,QWHUUXSW0DS5HJLVWHUV,QLWLDOL]DWLRQ&RGH 

Página 58 - 36 Interphase Corporation

List of Examplesx Interphase Corporation

Página 59

4538 Hardware Reference Manual xiUsing This GuidePurposeThis 4538 Hardware Reference Manual is designed for software developers in Interphase customer

Página 60 - Multiplex Direct Mode

Byte Ordering and Bit Coding Conventionxii Interphase CorporationByte Ordering and Bit Coding ConventionThe PCI bus uses the Little Endian Byte orderi

Página 61

4538 Hardware Reference Manual xiiiCAUTIONThe Caution icon brings to your attention those items or steps that, if not properly followed, could cause p

Página 63

Checking and Downloading from the Interphase WWW/FTP Sitexiv Interphase CorporationChecking and Downloading from theInterphase WWW/FTP SiteThe latest

Página 64

4538 Hardware Reference Manual xvoperating system subdirectories. In these cases, you must choose the proper bus and operating system by typing cd <

Página 65

Checking and Downloading from the Interphase WWW/FTP Sitexvi Interphase Corporation

Página 66 - 44 Interphase Corporation

14538 Hardware Reference Manual 11Hardware DescriptionOverviewThe Interphase 4538 PMC E1/T1/J1 Communications Controller is a network interface PCI Me

Página 67

The PowerQUICC II2 Interphase Corporation4538 Hardware StructureFigure 1-1 shows the 4538 hardware structure:Figure 1-1. 4538 StructureThe PowerQUICC

Página 68 - 46 Interphase Corporation

Chapter 1: Hardware Description4538 Hardware Reference Manual 3• Three Fast Serial Communications Controllers (FCCs). One is used to control the Ethe

Página 69

The PowerQUICC II4 Interphase CorporationOnce all the resets are de-asserted, the PowerQUICC II boots using its 8-bit FLASH device.The MPC8260 can con

Página 70

Chapter 1: Hardware Description4538 Hardware Reference Manual 5local processor can also be cachable. The peripherals cannot be cachable. The area of S

Página 71

The PowerQUICC II6 Interphase CorporationFigure 1-2. Local Space Mapping0xF002 00000x0000 00000x8000 00000xC000 00000xCFFF FFFF0xF000 00000xFFFF FFFF

Página 72 - 50 Interphase Corporation

Chapter 1: Hardware Description4538 Hardware Reference Manual 7NOTEAccesses from the CPM and the PowerSpan cannot go through the Memory Management Uni

Página 73

Copyright Notice© 2001 by Interphase Corporation. All rights reserved.Printed in the United States of America, 2001.This manual is licensed by Interph

Página 74

The PowerQUICC II8 Interphase CorporationCommunication Processor Module (CPM) I/O PortsThe CPM part of the PowerQUICC II provides several communicatio

Página 75

Chapter 1: Hardware Description4538 Hardware Reference Manual 97DEOHCPM Port C Usage&30,23RUW 3LQ&RQILJXUDWLRQ 'LU 8VDJH3&

Página 76 - 54 Interphase Corporation

The PowerQUICC II10 Interphase CorporationCAUTIONThe I/O ports described as “Unused” in the tables above must be configured as general purpose outputs

Página 77

Chapter 1: Hardware Description4538 Hardware Reference Manual 11The two first TDM busses of each serial interface are connected to the four TDM busses

Página 78 - 56 Interphase Corporation

The PowerQUICC II12 Interphase CorporationThree Ethernet LEDs, LED3, LED4, and LED5, driven respectively by the LXT971A LED/CFG(1:3) outputs, are prov

Página 79

Chapter 1: Hardware Description4538 Hardware Reference Manual 13Figure 1-3. Board CPU_LEDsThe PCI Bridge A dedicated PCI bridge, the Tundra PowerSpan

Página 80 - 58 Interphase Corporation

The PCI Bridge14 Interphase CorporationThe PowerSpan internal register set can be split into six different functional groups:• PCI configuration regi

Página 81 - 24538 Power-Up Initialization

Chapter 1: Hardware Description4538 Hardware Reference Manual 15These registers are initialized with fixed reset values or with values stored in the I

Página 82 - Value Description

The PCI Bridge16 Interphase CorporationPowerSpan Processor Bus RegistersThese registers are used to define the parameters of the local to PCI windows.

Página 83 - [±[) [ 5HVHUYHG

Chapter 1: Hardware Description4538 Hardware Reference Manual 17PowerSpan DMA RegistersThese registers are used to control the four bidirectional DMA

Página 84 - 62 Interphase Corporation

AssistanceProduct Purchased from ResellerContact the reseller or distributor if• You need ordering, service or any technical assistance.• You receiv

Página 85 - PowerQUICC II Initializations

The PCI Bridge18 Interphase CorporationPowerSpan Miscellaneous RegistersThis group of registers includes several configuration registers for the inter

Página 86

Chapter 1: Hardware Description4538 Hardware Reference Manual 19PowerSpan I²O RegistersThe PowerSpan includes I²O messaging queues controlled by sever

Página 87

The PCI Bridge20 Interphase CorporationInterrupt pins –INT1 to –INT4 are configured as output ports and conventionally associated with doorbell bits D

Página 88 - Cache Initialization

Chapter 1: Hardware Description4538 Hardware Reference Manual 21Local to PCI Interrupt (–INTA)The PowerQUICC II can generate an interrupt toward the P

Página 89 - CPM RCCR Reset

The PCI Bridge22 Interphase CorporationNOTEA PowerSpan PCI-to-Local window must have been enabled in the I²C serial EEPROM, in order to allow the Comp

Página 90 - 68 Interphase Corporation

Chapter 1: Hardware Description4538 Hardware Reference Manual 23Figure 1-4. Local Space Access From PCI Memory SpaceWhen the processor is running, th

Página 91 - 3Programming the Peripherals

The PCI Bridge24 Interphase Corporationdual port RAM, the QuadFALC framers, and the IMA device. (the processor must have its chip selects programmed).

Página 92 - 70 Interphase Corporation

Chapter 1: Hardware Description4538 Hardware Reference Manual 25On the 4538 board, the serial EEPROM content disables the windows. By default, no Loca

Página 93

The PCI Bridge26 Interphase CorporationFigure 1-5. PCI I/O or Memory Space Access from Local SpaceIn-situ EPLDs ProgrammingSome glue logic is impleme

Página 94

Chapter 1: Hardware Description4538 Hardware Reference Manual 27These devices keep their programming during power off. So the EPLD should normally be

Página 95 - Introduction

END-USER LICENSE AGREEMENTFOR INTERPHASE CORPORATION SOFTWAREIMPORTANT NOTICE TO USER–READ CAREFULLYTHIS END-USER LICENSE AGREEMENT FOR INTERPHASE COR

Página 96 - 74 Interphase Corporation

The PCI Bridge28 Interphase CorporationTable 1-24. Hardware Configuration Register Field DescriptionsField DescriptionMPC_ID Microprocessor identifie

Página 97 - TDM Busses General Structure

Chapter 1: Hardware Description4538 Hardware Reference Manual 29Vital Product Data (VPD)No VPD has been defined for the 4538.Interphase-Specific Produ

Página 98 - Multiplexed Direct Mode

The QuadFALC T1/E1/J1 Framer30 Interphase CorporationThe FLASH device is normally controlled by the PowerQUICC II memory controller unit using chip-se

Página 99

Chapter 1: Hardware Description4538 Hardware Reference Manual 31The QuadFALC includes a flexible clock unit that uses a clock supplied on its MCLK pin

Página 100 - Independent Direct Mode

The QuadFALC T1/E1/J1 Framer32 Interphase CorporationFor each line x, the QuadFALC provides four transmit multifunction ports (XPA_x, XPB_x, XPC_x and

Página 101 - Switched Mode

Chapter 1: Hardware Description4538 Hardware Reference Manual 33Each line of the QuadFALC framers can be configured independently in Line Termination

Página 102 - Pass-Through Mode

TDM Bus Configurations34 Interphase CorporationTDM Bus ConfigurationsGeneralThe TDM bus general structures are described in Figure 1-6 for the general

Página 103

Chapter 1: Hardware Description4538 Hardware Reference Manual 35Figure 1-6. TDM Busses General Structure5'2B5'2B;',B;',B03&am

Página 104 - T1 Specific Initialization

TDM Bus Configurations36 Interphase CorporationFigure 1-7. General Clock Structure (Framer 1 & 2)

Página 105 - Register Bit Value Comment

Chapter 1: Hardware Description4538 Hardware Reference Manual 37Figure 1-8. General Clock Structure (Framer 3 & 4)

Página 106 - The TTY Framer Initialization

Limitation of Liability: NEITHER INTERPHASE NOR ITS LICENSORS SHALL BE LIABLE FOR ANY GENERAL, INDIRECT, CONSEQUENTIAL, INCIDENTAL, OR OTHER DAMAGES A

Página 107

TDM Bus Configurations38 Interphase CorporationMultiplex Direct Mode In this mode, PA(7) = SWMODE_N = 1 and PA(0) = COMCLK_N = 1.In multiplex direct m

Página 108 - 86 Interphase Corporation

Chapter 1: Hardware Description4538 Hardware Reference Manual 39NOTETDMb1, TDMc1, TDMd1, TDMa2, TDMb2, TDMc2 and TDMd2 signals are not used and must b

Página 109 - Interrupt Pin Configuration

TDM Bus Configurations40 Interphase CorporationFigure 1-10. Clocks in Multiplex Direct Mode (Framer 1 & 2)

Página 110 - 88 Interphase Corporation

Chapter 1: Hardware Description4538 Hardware Reference Manual 41Figure 1-11. Clocks in Multiplex Direct Mode (Framer 3 & 4)

Página 111

TDM Bus Configurations42 Interphase CorporationIndependent Direct ModeIn this mode, PA(7) = SWMODE_N = 1 and PA(0) = COMCLK_N = 1.In independent direc

Página 112 - 90 Interphase Corporation

Chapter 1: Hardware Description4538 Hardware Reference Manual 436&/.54XDG)$/&7'0EB/5&/. 0+]GHMLWWHUHG5HFHLYH6\VWHP&

Página 113

TDM Bus Configurations44 Interphase CorporationNOTES RCLK2, RCLK3 and RCLK4 must be configured as inputs (PC5.CRP=0). XPA1, XPA2, XPA3 and XPA4 sh

Página 114 - 92 Interphase Corporation

Chapter 1: Hardware Description4538 Hardware Reference Manual 45Figure 1-12. TDM Busses in Independent Direct Mode5'2B5'2B;',B;&apo

Página 115 - In Situ EPLD Programming

TDM Bus Configurations46 Interphase CorporationFigure 1-13. Clocks in Independent Direct Mode (Framer 1 & 2)

Página 116 - PCI Deadlock Situations

Chapter 1: Hardware Description4538 Hardware Reference Manual 47Figure 1-14. Clocks in Independent Direct Mode (Framer 3 & 4)

Página 117 - 5Connectors and Front Panel

4538 Hardware Reference Manual iContentsList of Figures

Página 118 - -(WKHUQHW

TDM Bus Configurations48 Interphase CorporationSwitched ModeIn this mode, PA(7) = SWMODE_N = 0 and PA(0) = COMCLK_N = 1.In switched mode, the QuadFALC

Página 119

Chapter 1: Hardware Description4538 Hardware Reference Manual 49NOTETDMb1, TDMc1, TDMd1, TDMa2, TDMb2, TDMc2 and TDMd2 signals are not used and must b

Página 120 - 5['

TDM Bus Configurations50 Interphase CorporationFigure 1-16. Clocks in Switched Mode (Framer 1 & 2)

Página 121

Chapter 1: Hardware Description4538 Hardware Reference Manual 51Figure 1-17. Clocks in Switched Mode (Framer 3 & 4)

Página 122 - Table 5-5. PMC Connector P2

TDM Bus Configurations52 Interphase CorporationPass-Through ModeIn this mode, PA(7) = SWMODE_N = 1 and PA(0) = COMCLK_N = 0.Pass through is possible f

Página 123

Chapter 1: Hardware Description4538 Hardware Reference Manual 53NOTEUnused TDM signals must be tristated.)6&4XDG)$/&53$;3$53$;3$5

Página 124 - 102 Interphase Corporation

TDM Bus Configurations54 Interphase CorporationFigure 1-18. TDM Busses in Pass-Through Mode (1->2 & 3->4 Example)5'2B5'2B;&apos

Página 125 - PMC Connector P4

Chapter 1: Hardware Description4538 Hardware Reference Manual 55Figure 1-19. TDM Busses in Pass-Through Mode (2->1 & 4->3 Example)5'2B

Página 126 - 104 Interphase Corporation

TDM Bus Configurations56 Interphase CorporationFigure 1-20. Clocks in Pass-Through Mode (Framer 1 & 2)

Página 127 - Debug Port J5

Chapter 1: Hardware Description4538 Hardware Reference Manual 57Figure 1-21. Clocks in Pass-Through Mode (Framer 3 & 4)

Página 128 - Blank Card Jumper JP2

Contentsii Interphase CorporationPowerSpan I²O Registers

Página 129 - Carrier Card Specification

TDM Bus Configurations58 Interphase Corporation

Página 130 - ROW A ROW B ROW C ROW D ROW E

24538 Hardware Reference Manual 5924538 Power-Up InitializationOverviewAfter power-up, the STARTUP code is executed. This code is written entirely in

Página 131 - Custom Carrier Card

PowerSpan Initialization60 Interphase Corporation• PWRUP_BOOT=0: The PowerQUICC II boots locally (not through PCI)• PWRUP_DEBUG_EN=0:Disable debug m

Página 132 - 6435 Rear Transition Module

Chapter 2: 4538 Power-Up Initialization4538 Hardware Reference Manual 61Other PowerSpan InitializationsIt is necessary to initialize the PowerSpan Int

Página 133

PowerQUICC II Hardware Configuration Word62 Interphase CorporationExample 2-1. PowerSpan Interrupt Map Registers Initialization CodePowerQUICC II Har

Página 134 - 112 Interphase Corporation

Chapter 2: 4538 Power-Up Initialization4538 Hardware Reference Manual 63• MMR =11: External bus requests are masked (PQ2 is the boot master)• LBPC =

Página 135 - AMechanical Information

PowerQUICC II Initializations64 Interphase Corporation• LETM = 1: Enable Local Extended Transfer Mode• NPQM = 111: Non PowerQUICC II master connecte

Página 136 - 114 Interphase Corporation

Chapter 2: 4538 Power-Up Initialization4538 Hardware Reference Manual 65• APPC = 00: Address Parity pins used as local bus• CS10PC = 01:–CS10/–BCTL1

Página 137 - Bibliography

PowerQUICC II Initializations66 Interphase Corporation• Refresh the SDRAM eight times (OP=001)• Write the SDRAM Mode register (OP=011). For the main

Página 138 - Telecommunication Standards

Chapter 2: 4538 Power-Up Initialization4538 Hardware Reference Manual 67The instruction and data caches are enabled through bits ICE and DCE of regist

Página 139

Contents4538 Hardware Reference Manual iiiCPM RCCR Reset 

Página 140 - Manufacturers’ Documents

PowerQUICC II Initializations68 Interphase Corporation

Página 141

34538 Hardware Reference Manual 693Programming the PeripheralsOverviewThis chapter provides information specific to the 4538 board for peripheral prog

Página 142 - 120 Interphase Corporation

PowerQUICC II CPM Initialization70 Interphase Corporation• RFSDx = 01: Receive frame sync delay for TDMa. 01 for 1 clock delay.• DSCx = 0: Double sp

Página 143 - Glossary

Chapter 3: Programming the Peripherals4538 Hardware Reference Manual 71TDM Busses in Pass-Through ModeAccording to the TDM busses configuration (VHH7

Página 144

PowerQUICC II CPM Initialization72 Interphase CorporationFinal Result of SIxAMR (line 1 to 2 and line 3 to 4) and SIxBMR (line 2 to 1 and line 4 to 3)

Página 145

Chapter 3: Programming the Peripherals4538 Hardware Reference Manual 73Clocks and Baud-Rate GeneratorsIntroductionThe CPM contains eight independent,

Página 146

PowerQUICC II CPM Initialization74 Interphase CorporationMCCF1 register initialization:• Group 1 = 00: Group 1 (MCC channels 0-31) is used by TDMa1•

Página 147

Chapter 3: Programming the Peripherals4538 Hardware Reference Manual 75T1/E1/J1 Framer InitializationIntroductionThis section details the QuadFALC reg

Página 148

T1/E1/J1 Framer Initialization76 Interphase CorporationMultiplexed Direct ModeIn multiplex direct mode, the four framers have the same rhythm. SWMODE_

Página 149

Chapter 3: Programming the Peripherals4538 Hardware Reference Manual 77NOTEFor T1/J1 applications, the mapping of the receive 24 line time slots over

Comentários a estes Manuais

Sem comentários